ECOMAX® 6 NGS - Data sheet

Energy input
kW
1,558
Electrical output
kW
635
Available heat recovery
Engine circuit - hot H2O
kW
376
Exhaust gas fumes - hot H2O
kW
346
Total heat recovery as hot H2O
kW
722
or alternatively from exhaust
Steam at 8 bar - feedwater 90°C
kW
306
or
Thermal oil (from 180°C to 200°C)
kW
222
Electrical efficiency
%
40.8%
Thermal efficiency - hot H2O
%
46.0%
TOTAL efficiency
%
86.8%
NOx referred to 5% of O2
mg/Nm3
500