ECOMAX® 15 NGS - Data sheet

Energy input
kW
3.489
Electrical output
kW
1.497
Available heat recovery
Engine circuit - hot H2O
kW
897
Exhaust gas fumes - hot H2O
kW
636
Total heat recovery as hot H2O
kW
1.533
or alternatively from exhaust
Steam at 8 bar - feedwater 90°C
kW
544
or
Thermal oil (from 180°C to 200°C)
kW
348
Electrical efficiency
%
42.9%
Thermal efficiency - hot H2O
%
44.0%
TOTAL efficiency
%
86.9%
NOx referred to 5% of O2
mg/Nm3